USA, Canada |
|
B260IUNVHP | Basic-12® |
APPLICATION and PERFORMANCE SPECIFICATION |
|
Description High frequency electronic ballast for (2/1) F96T12ES (60W), (2/1) F96T12, (2/1) F84T12, (2/1) F72T12, (2/1) F64T12, (2/1) F60T12, (2/1) F48T12 or (2/1) F48T12ES (32W) |
|
• | Line Voltage: 120vac to 277vac, ±10%, 50Hz/60Hz |
|
• | Instant Start, Parallel Lamp Operation |
|
• | Active Power Factor Correction |
|
|
Lamps Type (#) |
Nominal Voltage |
Input Watts |
Nominal Line Amps |
Power Factor |
Ballast Factor |
Ballast Efficacy Factor |
Harmonic Total |
Crest Factor |
F96T12ES (2) 60W |
120 |
112 |
0.96 |
> 0.99 |
0.88 |
0.79 |
< 10% |
< 1.7 |
F96T12ES (2) 60W |
277 |
110 |
0.40 |
> 0.99 |
0.88 |
0.80 |
< 10% |
< 1.7 |
F96T12ES (1) 60W |
120 |
72 |
0.59 |
> 0.98 |
1.03 |
1.43 |
< 10% |
< 1.7 |
F96T12ES (1) 60W |
277 |
70 |
0.26 |
> 0.98 |
1.03 |
1.47 |
< 10% |
< 1.7 |
F96T12 (2) |
120 |
139 |
1.16 |
> 0.99 |
0.88 |
0.63 |
< 10% |
< 1.7 |
F96T12 (2) |
277 |
137 |
0.50 |
> 0.99 |
0.88 |
0.64 |
< 10% |
< 1.7 |
F96T12 (1) |
120 |
85 |
0.70 |
> 0.98 |
1.05 |
1.24 |
< 10% |
< 1.7 |
F96T12 (1) |
277 |
84 |
0.31 |
> 0.98 |
1.05 |
1.25 |
< 10% |
< 1.7 |
F84T12 (2) |
120 |
123 |
1.03 |
> 0.98 |
0.88 |
0.72 |
< 10% |
< 1.7 |
F84T12 (2) |
277 |
120 |
0.44 |
> 0.98 |
0.88 |
0.73 |
< 10% |
< 1.7 |
F84T12 (1) |
120 |
76 |
0.63 |
> 0.98 |
1.10 |
1.45 |
< 10% |
< 1.7 |
F84T12 (1) |
277 |
75 |
0.28 |
> 0.98 |
1.10 |
1.47 |
< 10% |
< 1.7 |
F72T12 (2) |
120 |
109 |
0.90 |
> 0.99 |
0.91 |
0.83 |
< 10% |
< 1.7 |
F72T12 (2) |
277 |
107 |
0.39 |
> 0.99 |
0.91 |
0.85 |
< 10% |
< 1.7 |
F72T12 (1) |
120 |
68 |
0.55 |
> 0.95 |
1.06 |
1.56 |
< 10% |
< 1.7 |
F72T12 (1) |
277 |
67 |
0.25 |
> 0.95 |
1.06 |
1.58 |
< 10% |
< 1.7 |
F64T12 (2) |
120 |
97 |
0.81 |
> 0.98 |
0.92 |
0.95 |
< 10% |
< 1.7 |
F64T12 (2) |
277 |
96 |
0.35 |
> 0.98 |
0.92 |
0.96 |
< 10% |
< 1.7 |
F64T12 (1) |
120 |
61 |
0.51 |
> 0.98 |
1.10 |
1.80 |
< 10% |
< 1.7 |
F64T12 (1) |
277 |
96 |
0.35 |
> 0.95 |
1.10 |
1.15 |
< 10% |
< 1.7 |
F60T12 (2) |
120 |
92 |
0.77 |
> 0.98 |
0.92 |
1.00 |
< 10% |
< 1.7 |
F60T12 (2) |
277 |
91 |
0.33 |
> 0.98 |
0.92 |
1.01 |
< 10% |
< 1.7 |
F60T12 (1) |
120 |
58 |
0.49 |
> 0.98 |
1.10 |
1.90 |
< 10% |
< 1.7 |
F60T12 (1) |
277 |
58 |
0.22 |
> 0.95 |
1.10 |
1.90 |
< 10% |
< 1.7 |
F48T12 (2) |
120 |
75 |
0.61 |
> 0.98 |
0.95 |
1.27 |
< 10% |
< 1.7 |
F48T12 (2) |
277 |
74 |
0.27 |
> 0.95 |
0.95 |
1.28 |
< 10% |
< 1.7 |
F48T12 (1) |
120 |
47 |
0.39 |
> 0.95 |
1.10 |
2.34 |
< 10% |
< 1.7 |
F48T12 (1) |
277 |
47 |
0.18 |
> 0.95 |
1.10 |
2.34 |
< 10% |
< 1.7 |
F48T12ES (2) 32W |
120 |
67 |
0.57 |
> 0.95 |
0.93 |
1.39 |
< 10% |
< 1.7 |
F48T12ES (2) 32W |
277 |
66 |
0.25 |
> 0.95 |
0.93 |
1.41 |
< 10% |
< 1.7 |
F48T12ES (1) 32W |
120 |
38 |
0.32 |
> 0.98 |
1.10 |
2.89 |
< 10% |
< 1.7 |
F48T12ES (1) 32W |
277 |
39 |
0.15 |
> 0.95 |
1.10 |
2.82 |
< 10% |
< 1.7 |
|
Application and Performance Specification Information Subject to Change without Notification. |
|
|
Performance |
• | Meets ANSI Standard C82.11-1993, Meets ANSI Standard C62.41-1991 |
|
• | Meets FCC Part 18 (Class A) for EMI and RFI Non-Consumer Limits |
|
• | Meets CSA Standard 654 for Ballast Efficiency |
|
|
Application |
• | Minimum Starting Temperature: 0°F (-18°C) – For ES lamps: 60°F (16°C) |
|
• | Maximum Case Temperature: 167°F (75°C) |
|
|
• | Remote Mounting: 20 ft. (6.1m) max. lead length, 18 AWG |
|
|
Safety |
|
• | UL listed (Class P, Type 1 Outdoor, Type HL) |
|
|
|
Physical Parameters |
• | Length ′L′: 11.75" (298.5mm) |
|
• | Width ′W′: 3.13" (79.5mm) |
|
• | Height ′H′: 1.78" (45.2mm) |
|
• | Mounting Length ′M′: 11.14" (283.0mm) |
|
• | Mounting Width ′X′: 2.00" (50.8mm) |
|
• | Shipping Weight: approx. 4.7 lbs. (2.134kg) |
|
• | Lead Length: – White, Black 25" (± 1") — 635.0mm (± 25.4mm) – Red 68" (± 1") — 1727.2mm (± 25.4mm) – Blue 60" (± 1") — 1524.0mm (± 25.4mm) |
|
|
Manufactured in North America |
|
|
|
|
January 2010 | Ballast must be grounded in accordance with national and local electrical codes. ONE LAMP APPLICATION - Cap unused blue lead |
Specifications and information are nominal and are subject to change without notice.