TB Series Open Core & Coil Industrial Control Transformers |
• | Acme′s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized... without sacrificing secondary voltage stability beyond practical limits. |
|
• | Acme′s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety. |
|
• | Voltage regulation of Acme′s TB Series transformers exceeds standards recommended by the National Electrical Manufacturers Association. |
|
• | Secondary circuit voltage drop between no-load and momentary overload remains exceptionally low. |
|
• | This excellent secondary circuit voltage regulation assures reliable operation of electromagnetic components and may permit the use of a smaller and less expensive industrial control transformer. |
|
|
|
|
|
|
|
Features |
• | 600 volt class and below. |
|
|
• | 80°C temperature rise, 130°C insulation class. |
|
• | Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency. |
|
• | Designs incorporate precision split bobbin wound coils for improved regulation. |
|
• | Primary fuse blocks and secondary fuse kits available and easily adaptable. |
|
• | Series-parallel connecting links save wiring and labor costs. |
|
• | Terminal blocks allow full access for ring terminals for easy installation even with solid strand conductors. |
|
• | Integrally molded terminal blocks with isolation barriers to prevent arc over. |
|
• | Footprint matches TA Series for easy interchangeability. |
|
• | Copper windings on all groups. |
|
• | Heavy gauge steel mounting plate adapts to various mounting dimensions. |
|
• | Voltage regulation exceeds NEMA requirements. |
|
• | UL Listed and CSA Certified. |
|
• | Meets or exceeds UL, CSA, NEMA, ANSI and OSHA Standards. |
|
|
|
|
Products |
Catalog No. |
VA |
Output |
Prim. Fuse Block |
Sec. Fuse Kit |
Sec. Fuse Size |
Dim. A (mm) |
Dim. B (mm) |
Dim. C (mm) |
|
TB-69300 |
50VA |
0,43A |
PL-112700 |
* |
6/10 Amp |
4.44" (11.3) |
3.00" (7.6) |
2.70" (6.8) |
|
TB-69301 |
100VA |
0.87A |
PL-112700 |
* |
1-4/10 Amp |
5.21" (13.2) |
3.00" (7.6) |
2.70" (6.8) |
|
TB-69302 |
150VA |
1.30A |
PL-112701 |
* |
2 Amp |
5.10" (13.0) |
3.75" (9.5) |
3.40" (8.6) |
|
TB-69303 |
250VA |
2.17A |
PL-112702 |
* |
3-1/2 Amp |
5.38" (13.7) |
4.50" (11.4) |
3.84" (9.8) |
|
|
350VA |
3.04A |
PL-112703 |
* |
5 Amp |
5.90" (15.0) |
4.65" (11.8) |
4.15" (10.5) |
|
TB-69305 |
500VA |
4.35A |
PL-112704 |
* |
7 Amp |
6.22" (15.8) |
5.25" (13.3) |
4.47" (11.4) |
|
TB-69306 |
750VA |
6.52A |
PL-112705 |
* |
10 Amp |
6.82" (17.3) |
6.75" (17.1) |
5.78" (14.7) |
|
TB-69307 |
1000VA |
8.70A |
PL-112705 |
* |
12 Amp |
7.96" (20.2) |
6.75" (17.1) |
5.78" (14.7) |
|
|
|
* See fusing chart for secondary fuse kits. |
|
|
|
|
|
|
|
|
TB Series Protective Devices: Secondary Fuse Kits |
Catalog No. |
Description |
|
PL79924 |
Fuse Kit: Secondary Fuse 1/4" x 1-1/4" w/ARM |
|
PL79928 |
50VA-350VA, Link: Small Jumper Links (Qty. 2) |
|
PL79929 |
500VA & 750VA, Link: Large Jumper Links (Qty. 2) |
|
PL79930 |
50VA-350VA, Fuse Kit: Secondary Fuse Midget w/ARM |
|
PL79931 |
500VA & 1000VA, Fuse Kit: Secondary Fuse Midget w/ARM |
|
|
|
|
|
|
|
|
|
Further Products |
Product image |
Product group and Description |
|
|
Industrial Control Transformers 50VA through 1000VA, 208/230/460 Primary Volts, 115 Secondary Volts, Single Phase, 50/60Hz |
|
|
Select desired product group above to get further informations. |
|
|
|
Specifications and information are nominal and are subject to change without notice.